Permit: T04CM05260

Parcel: 12601003C

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T04CM05260

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
01/11/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :* 1) SOIL WATER TEST IS OK 2) OVERHEAD WATER DISTRIBUTION IS OK 3) WASTE & VENT SYSTEM IS OK 4) OK FOR DRY WALL
12/30/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)CAN NOT REDUCE OUTLET OF GREASE TRAP TO 3". IF OUTLET IS 4" THEN DRAIN SHALL BE 4" TO P.O.C. 2)SHALL PROVIDE VENT FOR GREASE TRAP 3)RE TEST THE SYSTEM