Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T04CM05246
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/05/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* 1) SOIL WATER TEST IS OK 2) P.O.C. OF NEW BLDG DRAIN TO EXISTING BLDG DRAIN IS OK 3) NOTE: 4" FLOOR CLEANOUT IS LOCATED ON OPPISITE SIDE OF WALL 4) SHALL REMOVE BLAKE TEST TEE LOCATED UNDER SLAB AND REPLACE WITH SOLID 4" PIPE. NO THREADED FITTING MAY BE LOCATED IN A NON ACCESSIBLE LOCATION 5) OK TO BACKFILL TRENCH |