Permit: T04CM05246

Parcel: 12801005H

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T04CM05246

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
05/05/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
1) SOIL WATER TEST IS OK
2) P.O.C. OF NEW BLDG DRAIN TO EXISTING BLDG DRAIN IS OK
3) NOTE: 4" FLOOR CLEANOUT IS LOCATED ON OPPISITE SIDE OF WALL
4) SHALL REMOVE BLAKE TEST TEE LOCATED UNDER SLAB AND REPLACE WITH SOLID 4" PIPE. NO THREADED FITTING MAY BE LOCATED IN A NON ACCESSIBLE LOCATION
5) OK TO BACKFILL TRENCH