Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/16/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/02/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) ANCHOR BOLTS MISSING. 2) PLAN CALLS FOR SIMPSON EPC 66 AT6 ENDS OF GLU-LAM. 3) NEED LADDER FOR ROOF ACCESS. | |
| 04/14/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DBL LPI EACH SIDE OF STAIRWELL 2) EXTERIOR SHEATHING HORIZONTAL JOINTS HIT BETWEEN DBL TOP PLATE (WILL NEED SIMPSON LTFA OR EQUIV.) 3) ? MISSING GARAGE AND THRU-OUT 4) LEDGER BOLTS MISSING GARAGE 5) NEED BEAM TO POST CONNECTORS 6) WILL NEED WALK DECK LEDGER ATTACHMENT AND DETAIL APPROVED BY ENGINEER (NEED GOOD POSITIVE CONNECTION) 7) STOPPED INSPECTION |
|
| 04/11/2005 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | IVRS - RI canceled | |
| 04/08/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) A35'S OK LEDGER TO STUDS 2) OK TO COVER |