Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM05243

Parcel: 116213880


Addresses:

450 S STEPHANIE LP

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/16/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/02/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :* 1) ANCHOR BOLTS MISSING. 2) PLAN CALLS FOR SIMPSON EPC 66 AT6 ENDS OF GLU-LAM. 3) NEED LADDER FOR ROOF ACCESS.
04/14/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DBL LPI EACH SIDE OF STAIRWELL
2) EXTERIOR SHEATHING HORIZONTAL JOINTS HIT BETWEEN DBL TOP PLATE (WILL NEED SIMPSON LTFA OR EQUIV.)
3) ? MISSING GARAGE AND THRU-OUT
4) LEDGER BOLTS MISSING GARAGE
5) NEED BEAM TO POST CONNECTORS
6) WILL NEED WALK DECK LEDGER ATTACHMENT AND DETAIL APPROVED BY ENGINEER (NEED GOOD POSITIVE CONNECTION)
7) STOPPED INSPECTION
04/11/2005 EXT METAL CLIPS/EXT SHEATHING Cancelled IVRS - RI canceled
04/08/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) A35'S OK LEDGER TO STUDS
2) OK TO COVER