Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/27/2005 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection :* RECEIVED LETTER FROM VAUGHN HILL P.E GIVING OK. FOR NO TRAP PRIMERS TO KITCHEN AREA FLOOR DRAINS. |
| 04/19/2005 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection :* 1) INSTALL T/K COPPER UNDERSLAB FOR H20 TO BAR AREA. 2) INSTALL TRAP PRIMERS PER NOTES OR PROVIDE LETTER STAMPED & SEALED FROM ARCH & OWNER STATING FLOORS WILL BE ?? MOPED LIBERALLY. SO FLOOR DRAINS WILL RETAIN T-TRAP SEAL AT P-TRAP. 2" T/K H20 SERVICE INSTALLED UP & OUT OF NORTH WEST CORNER OK. 100 PSI AIR TEST |
| 04/18/2005 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 04/14/2005 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection :* PARTIAL APPROVED WATER TEST WASTE & VENT UNDERGROUND LAV AREA 108 & 109 OK |
| 04/12/2005 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection :* WATER TEST GREASE WASTE UNDERGROUND OK WATER TEST UNDERGROUND SANITARY DRAINAGE OK EXCEPT. 1) LAVS & FLOOR DRAINS IN ROOMS 108 7 109 REQUIRE CORRECT DRAINAGE FITTING AT DOUBLE WYE LOCATION WITH CORRECT END OF LINE CLEANOUTS. 2) WILL NEED TO VIEW PIPE WRAPS & UNDERSLAB H20 PRIOR TO CONCRETE POUR. |
| 04/08/2005 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection :* |