Permit: T04CM05237

Parcel: 141175240

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/13/2005 BUILDING - FINAL Approved IVRS - Inspection :*
05/11/2005 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) ELECTRIC SERVICE RISER NOT CONNECTED TO SERVICE PANEL-HUB BROKEN
2) FILL OPEN KNOCKOUTS IN SERVICE PANEL
3) SHEET METAL SCREWS ARE NOT ALLOWED TO SECURE SERVICE PANEL DEAD FRONT
4) GARAGE NORTH OUTLET NOT GFCI PROTECTED