Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM05233
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/17/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
02/16/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) END NAIL DRAG TRUSS, 6" ON CENTER 2) ADD A3.5 F TO #5 SHEAR WALL REAR 1`6" ON CENTER TOE NAIL TO TOP PLATE, TRUSS BOTTOM CHORD 12" ON CENTER 3) NEED SHEAR TRANSFER 10/DT1 GARAGE SHEAR 4) ADD TRUSS BRACING AT DROP CEILING TRUSSES 5'-2" ON CENTER |