Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/11/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 05/09/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPAIR WALL NORTH SIDE VENT PENETRATION 2) SEE INSPECTION DATED 5/5/5 |
|
| 05/05/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ADDRESS NUMBER 2) A/C DISCONNECT AND WHIP NOT SECURE 3) GARAGE OUTLETS MUST BE GFCI PROTECTED OR DEDICATED 4) NO GAPS ALLOWED AROUND ELECTRIC OUTLETS 5) MASTER BATH TOILET HAS ONLY 14" CLEARANCE FROM CENTER LINE TO WALL 15" REQUIRED 6) INSULATION CERTIFICATE STATES 10.3" CELLULOSE-LESS THAN 6" IN MANY AREAS 7) NO INSULATION DEPTH GASES 8) SUPPORT AND SECURE GAS LINE IN ATTIC TO SUPPORT HINGE JOINT |
|