Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/22/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/21/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING R/BLOCKING @ SEPARATING WALL. 2) MISSING R/BLOCKING THROUGHOUT. 3) X BRACE TRUSSES. 4) SUPPORT KITCHEN DROP |
|
| 03/18/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* NOT READY | |
| 03/17/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) DRAFT STOP MISSING. 2) NEED SHEET ROCK BEHIND TUBS |