Permit: T04CM05217

Parcel: 116161050

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/21/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :* 1) CORRECTIONS MADE OK 2) ABS DWV THRU ROOF OK WATER TEST OK. 3) PEX WATER PIPING OK SUBJ TO PLAN. 4) OK TO COVER ALL AREAS. 5) CLOSET FLANGES OK. 6) TUBS OK
03/18/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) CANNOT LOCATE A HORIZONTAL VENT BELOW THE FLOOD RIM LEVEL. 2) RE TEST SYSTEM.
03/15/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :* 1) PLEASE REAPIR LEAK AT METER-OK TO COVER THE REST. 2) ABS RE-ROUGHED AND COVERED WHERE VENT CONNECTS TO HORIZONTAL DRAIN, INVERT TO BE ABOVE DRAINAGE CENTER LINE. 3) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP. 9) 2ND FLOOR CLOSET FLANGES TO BE SECURED WITH S SCREWS OR BRASS SCREWS. 5) SEE PLUMBING NOTE # 7 SINCE PB IS NOT ALLOWED-WATER TO BE COPPER.