Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/20/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/19/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR BLOCKING PANELS NOT NAILED PER 6/SD-2 2) RED HEAD ANCHOR BOLTS LOOSE-PROVIDE ICBO INSTALLATION INSTRUCTIONS 3) SECOND FLOOR SILL PLATES NOT NAILED TO FLOOR PER NAIL SCHEDULE 4) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 5) INSTALL ROOF VENTS 6) DBL 2 X CRIPPLE MISSING EAST WINDOW |
|
| 05/17/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 05/16/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JAMES |
|
| 05/11/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) STUCCO VAPOR BARRIER MISSING SOUTH WALL 2) SHEAR BLOCKING PANELS MUST BE NAILED PER 6/SD2 3) ALUS 48 MISSING NAILS 4) RED HEAD ANCHOR BOLTS LOOSE PROVIDE ICBO APPROVED INSTALLATION INSTRUCTIONS 5) KITCHEN SINK NOT VENTED TO ROOF-SEE PLAN 6) ELECTRIC WIRES MUST TERMINATE IN APPROVED ELECTRIC BOXES 7) F2A TRUSSES NOT PROPERLY BEARING ON HEADER 8) DO NOT SHIM 9) STOPPED INSPECTION, TO MANY ITEMS |
|
| 05/09/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |