Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM05179
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/08/2005 | FRAMING | Approved | IVRS - Inspection :* 1) OK TO INSULATE 2) SUPPORT 2ND FLOOR ABS EVERY 4' |
|
04/07/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NAIL OFF STRAP TO GLU LAM IN KITCHEN 2) COMPLETE WIRING IN ISLAND 3) NAIL STRAPS TOP PLATE UPSTAIRS BATH 4) NAIL STRAPS TOP PLATE IN BONUS ROOM 5) NO DWV TEST 6) SUPPLY OK 7) NEED 1" CLEARANCE TO B-VENT |