Permit: T04CM05170

Parcel: 140376180


Addresses:

6925 S GOSHAWK DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/07/2005 FRAMING Approved IVRS - Inspection :*
04/04/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) ANCHOR BOLTS LOOSE THROUGHOUT
2) FIRESTOP CHASE IN GARAGE
3) HOLDOWN MORE THAN 8" FROM END OF GARAGE SHEARWALL. BOLT TO SHORT
4) W/H "B" VENT WITHIN 1" OF COMBUSTIBLE MATERIAL
5) 2" DRAIN AT KITCHEN DOES NOT HAVE 1/4" PER FOOT SLOPE. FLAT, ALSO 3"
6) STOPPED INSPECTION, TO MANY ITEMS
7) SUPERINTENDENT TO INSURE HOUSE IS COMPLETE PRIOR TO NEXT INSPECTION