Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/06/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/01/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPLACE 2 X 4 BEARING STUDS AT KITCHEN WALL 2) PROVIDE ENGINEERING FOR CUT IN POST TENSION SLAB FOR ELECTRIC UNDERGROUND 3) DBL TOP PLATE SPLICE RIGHT SIDE OF SLIDER THAN 24" 4) FLEX DUCT PENETRATION THROUGH SHEAR PANELS 5) SECURE 4 GANG BOX 6) COMPLY WITH 7SD3 AND 4SD4 |
|
| 03/31/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHIM HEADER NORTH OF STAIRS-2ND FLOOR 2) FINISH X BRACING 3) FIREBLOCK MASTER WINDOW CHASES 4) BLOCK LAUNDRY DUCT BOOT 5) NAIL OFF GARAGE HIP BRACKETS |