Permit: T04CM05144

Parcel: 116193660


Addresses:

525 N BONITA AV


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T04CM05144

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
03/09/2007 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
10/27/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST EXTERIOR WALL -- GRID LINE 6 FROM G TO J
TOP OUT
10/26/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT AT FRONT COLUMNS
10/20/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
5 COLUMN ON CENTER 16'
10/18/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT AT ENTRY LINE 6, 3RD LIFT COLUMN NORTH END
10/13/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12' ON FRONT COLUMNS
10/12/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
NO REBAR
10/04/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
10/03/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LIFT ON FRONT COLUMNS
09/29/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
INCOMPLETE
09/27/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT LINE J, 3RD LIFT LINES G-I
09/22/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT SOUTH WALL
2ND LIFT LINE G
09/20/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
4TH LIFT LINE G
TOP OUT LINE M
09/18/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
INCOMPLETE
09/14/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINE M, 1-4 3RD LIFT LINE 0 - 4-8
09/12/2006 REINFORCED MASONRY PRE-GROUT Partial Approval 2ND LIFT LINE J-O
3RD LIFT LINE 0-4
09/11/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection INCOMPLETE
09/06/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINE O-8 8-J
2ND LIFT
09/05/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
G-5-1 LINE 8-B
08/29/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
GRIDLINE J-8
08/25/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
4TH LIFT 8 - A-G, A 2-8, 2 A-G
3RD LIFT G 2-5, G 5.3-8
1ST LIFT L 1-5, 1 L-M
08/22/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
3RD LIFT ON EAST WALL, NORTH WALL, WEST WALL
NORTH HALF OF BUILDING
08/16/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
2ND LIFT CENTER NORTHWALL, 1ST LIFT SOUTH WALL.
08/10/2006 REINFORCED MASONRY PRE-GROUT Partial Approval GRIDLINE 8-F 2ND LIFT
LINE 2 - OK 2ND LIFT
LINE A - 8
LINE 5-L 1ST LIFT
08/09/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
MISSING REBAR
08/07/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
2ND LIFT NORTH WALL
08/04/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT GRIDLINE G-5
08/02/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT
GRIDLINE 2-LL
A-8
8-LL
06/30/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MAIN BUILDING STEM OK