Permit: T04CM05141

Parcel: 120070360


Addresses:

150 W PRESIDENT ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/12/2006 BUILDING - FINAL Approved IVRS - Inspection :*
09/06/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. ANTI-TIP ON RANGE (REPEAT)
2. CLAMP WATER HTR WHIP (REPEAT)
3. 15 AMP BREAKERS ON 14 AWG WIRE (REPEAT)
4. BUBBLE COVERS MUST BE OPERABLE (REPEAT)
5. WASHER DRAIN REQ'S P-TRAP (REPEAT)
6. DISHWASHER DRAIN MUST BE CLAMPED TO BOTTOM OF COUNTER.
7. PROVIDE LADDER
8. REFEE WILL APPLY
04/10/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
10 NO ACCESS 8:15 AM
03/13/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ACCESS 2:20 PM
02/13/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL ANTI-TIP DEVICE ON STOVE
2) BRING DISPOSAL RECEPTACLE OUT FLUSH TO SURFACE
3) SMOKIES REQUIRED TO BE 6"-12" FROM CEILING
4) SMOKIES IN BEDROOMS REQUIRE ARC FAULTS
5) 14 AWG WIRE REQUIRES 15 AMP MAX BREAKER
6) CLAMP WATER HTR WHIP 12" FROM DISCONNECT
7) ENCLOSE WATER HTR
8) EXT. GFI COVERS MUST BE OPERABLE
9) NON-METALLIC PIPING LABEL
10) COMPLETE WASHER DRAIN
11) NO ROOF ACCESS
12) STOPPED INSPECTION