Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM05132
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/07/2005 | FRAMING | Approved | IVRS - Inspection :* | |
02/03/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) CHANGE TECO NAILS ON PORCH POSTS TO 16D 2) OK TO SHEETROCK |
|
02/02/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NAILS ON PORCH 2) POST HARDWARE TO BE 16D'S 3) OK TO INSULATE 4) NAIL PLATES ROMEX IN LAUNDRY |
|
02/01/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) BANG PLATE ROMEX IN GARAGE AT TOP PLATES, ALSO IN LAUNDRY MARKED ON FLOOR 2) PROTECT H20 SERVICE AT GARAGE FHA STRAP 3) PROTECT A/C LINE SET FROM FHA STRAP SOUTH WALL AT TOP PLATE, BLOCK STRAP A/C LINE AT EXT. TERMINATION THRU WALL 4) INTERIOR BEARING WALL WEST OF GARAGE SHEARWALL, H2.5 EACH STUD TO TOP PLATE, SHIM AT BEARING PT. 5) BROKEN BANG PLATE SOUTH BATH 6) BENT STUD AT 4 SWITCH BOX LIVING ROOM 7) ALL TRUSS TO TOP PLATES AT 10/DT1 GET H2.5 TRUSS TO TOP PLATE HEADER BEAM INSTALLED IN LIVING ROOM WALL TIE TOGETHER H2.5'S 8) A HUS 26 HANGER AT TRUSS, TO GIRDER 10D X 1 1/2" NAIL USED FOR GOOD FOR 64 PERCENT OF 16D COMMON REQUIRED BY MANUFACTURER, HANGER SIZE NOT LISTED ON PLAN 9) REAR PORCH POST HARDWARE REQUIRES 16D COMMONS 10D X 1 1/2" INSTALLED 10) NORTH EAST BATHROOM, DOES WALL NEED TO BE FURRED OUT ? 11) FINISH LATH |
|
01/31/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* MUST CP ALL LATHE NO PLANS/PERMIT STOPPED INSP |