Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM05132

Parcel: 136100710

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM05132

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/07/2005 FRAMING Approved IVRS - Inspection :*
02/03/2005 FRAMING Partial Approval IVRS - Inspection :*
1) CHANGE TECO NAILS ON PORCH POSTS TO 16D
2) OK TO SHEETROCK
02/02/2005 FRAMING Partial Approval IVRS - Inspection :*
1) NAILS ON PORCH
2) POST HARDWARE TO BE 16D'S
3) OK TO INSULATE
4) NAIL PLATES ROMEX IN LAUNDRY
02/01/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) BANG PLATE ROMEX IN GARAGE AT TOP PLATES, ALSO IN LAUNDRY MARKED ON FLOOR
2) PROTECT H20 SERVICE AT GARAGE FHA STRAP
3) PROTECT A/C LINE SET FROM FHA STRAP SOUTH WALL AT TOP PLATE, BLOCK STRAP A/C LINE AT EXT. TERMINATION THRU WALL
4) INTERIOR BEARING WALL WEST OF GARAGE SHEARWALL, H2.5 EACH STUD TO TOP PLATE, SHIM AT BEARING PT.
5) BROKEN BANG PLATE SOUTH BATH
6) BENT STUD AT 4 SWITCH BOX LIVING ROOM
7) ALL TRUSS TO TOP PLATES AT 10/DT1 GET H2.5 TRUSS TO TOP PLATE HEADER BEAM INSTALLED IN LIVING ROOM WALL TIE TOGETHER H2.5'S
8) A HUS 26 HANGER AT TRUSS, TO GIRDER 10D X 1 1/2" NAIL USED FOR GOOD FOR 64 PERCENT OF 16D COMMON REQUIRED BY MANUFACTURER, HANGER SIZE NOT LISTED ON PLAN
9) REAR PORCH POST HARDWARE REQUIRES 16D COMMONS 10D X 1 1/2" INSTALLED
10) NORTH EAST BATHROOM, DOES WALL NEED TO BE FURRED OUT ?
11) FINISH LATH
01/31/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
MUST CP ALL LATHE
NO PLANS/PERMIT
STOPPED INSP