Permit: T04CM05123

Parcel: 13348128D

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T04CM05123

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
01/04/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
12/30/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/REPAIR LEAK AT 4X3 COMBO AT TRANSITION BAND BELOW LAV AND CALL IN FOR INSPECTION PRIOR TO CONCFRETE.
12/29/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*/1)NOT INSTALLED PER PLAN. NO TEST ON SYSTEM. SANTEE MAY NOT LAY ON ITS BACK. A FURNCO IS NOT APPROVED UNDER THE BLDG. PIPING TO BE SUPPORTED TO TABLE 3-1 94 UPC. UNABLE TO SEE OVER HEAD. 2)PENCILED IN CHANGES NOT ACCEPTED. INSPECTION STOPPED.
12/23/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*