Permit: T04CM05122

Parcel: 138230060


Addresses:

643 W CALLE MEDINA

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/24/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
01/21/2005 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
01/20/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GAS LINE MUST BE 12" BELOW GRADE
2) BLACK PIPE CANNOT BE BENT FOR CHANGE IN DIRECTION
3) EXPOSE ALL PIPE COUPLINGS AND FITTINGS FOR INSPECTION OF PRIMER AND TAPE
4) EXTEND GAS NIPPLE OUT OF WALL CAVITY