11/30/2004 ROOF NAILING Approved IVRS - Inspection :*
11/24/2004 ROOF NAILING Denied IVRS - Inspection GAS LINE CANNOT RUN UNDER SLAB IN COVERED ROOM
SHUT OFF VALVE REQUIRED UPSTREAM OF GROUND UNION
GAS LINE MUST BE 12" UNDER GROUND
NO GAS PRESSURE TEST
#6 GROUND WIRE NOT ALLOWED ON EXTERIOR OF BUILDING, INSTALL TWO GROUND RODS 6 FEET APART CONNECTED TO PANEL WITH A CONTINOUS #4 CONDUCTOR
REPLACE DAMAGED ROOF SHEATHING - REMOVE SLAB REPAIR
POTABLE WATER PLUMBING NOT COMPLETE
NAIL PROTECT ALL PLUMBING WITHIN 1 1/4" OF STU SURFACE
DRYER VENT NOT IN
GROUND ALL METAL ELECTRIC BOXES
NAIL PROTECT ALL WIRES