Permit: T04CM05118

Parcel: 141175100

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM05118

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/16/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/14/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NO TRUSS DRAWINGS ON SITE
2) 10/DT1 NOT COMPLIED WITH
3) EXTERIOR CLIP ITEMS NOT COMPLIED WITH
02/10/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO LATH AND DRY IN ROOF
2) A-1 TRUSS RAT RUNS CHECK SHOP DRAWINGS FOR CORRECT BRACING
3) AT INTERMEDIATE INSPECTION CHECK A.35'S AT SHEAR WALL
4) A.35'S AT 12" ON CENTER GARAGE FRONT WING WALLS TO TRUSS CHORD
02/09/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) GARAGE SHEAR WALL (HOUSE TO GARAGE) IS A #6 REQUIRES A3.5 AT 12" ON CENTER PLATE TO TRUSS
2) AT GARAGE FRONT SHEAR #6 A3.5 12" ON CENTER TRUSS TO SHEAR ON INSIDE OF WALL REQUIRES A ST2115 STRAP (3/4" WIDE, 16 1/2" LONG=10 16D'S)
3) NAIL FRIEZE BLOCKS AT EAST OVERHANG
4) INSTALL RAT RUNS ON A-1 TRUSSES, (7-A-1'S)