Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM05118
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/16/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
02/14/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NO TRUSS DRAWINGS ON SITE 2) 10/DT1 NOT COMPLIED WITH 3) EXTERIOR CLIP ITEMS NOT COMPLIED WITH |
|
02/10/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO LATH AND DRY IN ROOF 2) A-1 TRUSS RAT RUNS CHECK SHOP DRAWINGS FOR CORRECT BRACING 3) AT INTERMEDIATE INSPECTION CHECK A.35'S AT SHEAR WALL 4) A.35'S AT 12" ON CENTER GARAGE FRONT WING WALLS TO TRUSS CHORD |
|
02/09/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) GARAGE SHEAR WALL (HOUSE TO GARAGE) IS A #6 REQUIRES A3.5 AT 12" ON CENTER PLATE TO TRUSS 2) AT GARAGE FRONT SHEAR #6 A3.5 12" ON CENTER TRUSS TO SHEAR ON INSIDE OF WALL REQUIRES A ST2115 STRAP (3/4" WIDE, 16 1/2" LONG=10 16D'S) 3) NAIL FRIEZE BLOCKS AT EAST OVERHANG 4) INSTALL RAT RUNS ON A-1 TRUSSES, (7-A-1'S) |