Date Description Inspector Results Comments
03/28/2005 FRAMING Approved IVRS - Inspection :*
03/27/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) UPSTAIRS CHASE BETWEEN MASTER AND BEDROOM 3 3/4" FIRESTOP NEEDED
2) ACCESS PANEL NEEDED FOR GFI UPSTAIRS JACCUZZI
3) OVERKNOTCHED STUD AT JACCUZZI TUB
4) BUSTED GUAGE
5) COMPLY WITH UPSTAIRS 10/SD-4
03/21/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRESTOP TUB SHOES
2) FIRESTOP W/H FLUE 1ST FLOOR
3) FIRESTOP OVERKNOTCH TOP PLATE PAINTS A/C LINES
4) SEAL ALL PENETRATIONS
5) HOME RUNS IN GARAGE AND 220 LINES CUT IN GARAGE
6) NAIL PROTECT TOP PLATES DOWNSTAIRS BATH
7) STOPPED INSPECTION
03/17/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STRAP BOX HEADER AT GARAGE WEST WALL
2) BOLT MISSING GARAGE SHEAR WALL HOLDOWN
3) BLACK REGISTER LAUNDRY ROOM 3 SIDES
4) FIRESTOP WATER HEATER FLU THROUGH 1ST FLOOR
5) FIRESTOP TUB SHOES
6) SEAL PRESSURE RELIEF
7) SEAL A/C 220 LINE
8) RANGE 220 EXTERIOR OF WALL
9) TERMINATE A/C 220 TO EXTERIOR
10) PEX NOT PRESSUREIZED
11) NAIL PROTECT PLUMBING DOWNSTAIRS BATH TOP PLATE
12) FIRESTOP OVERKNOTCH PANTRY TOP PLATE AT PLUMBING
13) FIRESTOP OVERKNOTCH A/C LINES TOP PLATES AND 1ST FLOOR AT KITCHEN
14) A.35 NEEDED AT STAIRWAY LANDINGS
15) FIREBLOCK MISSING AT STAIRWELL
16) BLOCK BATH REGISTER 3 SIDES
17) STOPPED INSPECTION AT 1ST FLOOR