Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM05094
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/28/2005 | FRAMING | Approved | IVRS - Inspection :* | |
03/27/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) UPSTAIRS CHASE BETWEEN MASTER AND BEDROOM 3 3/4" FIRESTOP NEEDED 2) ACCESS PANEL NEEDED FOR GFI UPSTAIRS JACCUZZI 3) OVERKNOTCHED STUD AT JACCUZZI TUB 4) BUSTED GUAGE 5) COMPLY WITH UPSTAIRS 10/SD-4 |
|
03/21/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRESTOP TUB SHOES 2) FIRESTOP W/H FLUE 1ST FLOOR 3) FIRESTOP OVERKNOTCH TOP PLATE PAINTS A/C LINES 4) SEAL ALL PENETRATIONS 5) HOME RUNS IN GARAGE AND 220 LINES CUT IN GARAGE 6) NAIL PROTECT TOP PLATES DOWNSTAIRS BATH 7) STOPPED INSPECTION |
|
03/17/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STRAP BOX HEADER AT GARAGE WEST WALL 2) BOLT MISSING GARAGE SHEAR WALL HOLDOWN 3) BLACK REGISTER LAUNDRY ROOM 3 SIDES 4) FIRESTOP WATER HEATER FLU THROUGH 1ST FLOOR 5) FIRESTOP TUB SHOES 6) SEAL PRESSURE RELIEF 7) SEAL A/C 220 LINE 8) RANGE 220 EXTERIOR OF WALL 9) TERMINATE A/C 220 TO EXTERIOR 10) PEX NOT PRESSUREIZED 11) NAIL PROTECT PLUMBING DOWNSTAIRS BATH TOP PLATE 12) FIRESTOP OVERKNOTCH PANTRY TOP PLATE AT PLUMBING 13) FIRESTOP OVERKNOTCH A/C LINES TOP PLATES AND 1ST FLOOR AT KITCHEN 14) A.35 NEEDED AT STAIRWAY LANDINGS 15) FIREBLOCK MISSING AT STAIRWELL 16) BLOCK BATH REGISTER 3 SIDES 17) STOPPED INSPECTION AT 1ST FLOOR |