Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/08/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/07/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 3 PT TRUSSES REQUIRE 5 POSTS 2) SOUTH GARAGE H.D. NUT/BOLT TO SHORT 3) FIRE STOP GARAGE AND FLOOR 4) SHIM GIRDER POST 5) SHIM 3 PT TRUSS OVER DIAGONAL WALL 6) BLOCK SHEAR WALL REPAIR |
|
| 04/04/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) LVL NOT NAILED AT 4" ON CENTER 2) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF WALL SURFACE 3) RELOCATE WIRES TOUCHING W/H "B" VENT 4) HOLDOWNS NOT INSTALLED GARAGE SHEARWALL DAMAGED 5) ANCHOR BOLTS LOOSE THROUGHOUT 6) STOPPED INSPECTION, TO MANY ITEMS 7) HAVE SUPERINTENDENT MAKE SURE HOUSE IS COMPLETE PRIOR TO NEXT INSPECTION |