Permit: T04CM05071

Parcel: 14044009G


Addresses:

7710 S WILMOT RD


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM05071

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/18/2006 FRAMING Approved IVRS - Inspection :*
01/17/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. DOUBLE STUDS REQUIRED END OF WALLS
2. NATIONAL GYP REQUIRES STUDS 16" OC MAX FOR PERMABASE CEMENT BOARD
3. 2X6 BOX HEADER REQUIRED AT LARGE OPENINGS
4. CLIPS FOR WOOD FRAME CEILING
5. WATCH 36" CLEAR @ NEW KITCHEN HALL
01/04/2006 FRAMING Partial Approval IVRS - Inspection :*
1) OK TO ROCK NORTH END FOR FRIDGE SET