Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM05067
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/26/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/14/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CLEARANCE TO COMBUSTIBLES AND FIRESTOP NEEDED AT SOUTH AND NORTH FLUES |
|
| 06/07/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NORTH WINDOW NOT MESHED |
|
| 06/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK OFF TOP OF WATER HEATER PLATFORM 2) BANG PLATE CONDENSATE 3) FINISH STRAPPING ALL NARROW TJI SHIM BLOCKS DOWN TO TOP PLATE 4) STRAP FIREPLACE FLUE AT 90 DEGREE 5) DBL HOLE BORES ON NORTH WALL BEARING STUDS ARE UN-ACCEPTABLE 6) NEED CAULKING 7) DAMAGED WIRE 1 BAY EAST OF HOME RUN ENTRY 8) BANG PLATE WIRES AT FRONT WINDOW H.D. 9) FLUE DISCONNECTED BELOW ROOF 10) FIREBLOCK FLUE CHASES AND COMBUSTIBLES ON SOUTH FLUE 11) DRYER FLUE DOES NOT PENETRATE ROOF 12) REPAIR CAN LIGHT BRACKET ON WALK DECK 13) POSSIBLE PONDING AREA BEHIND WALK DECK POSTS |