Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM05034
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/04/2005 | FRAMING | Approved | IVRS - Inspection :* | |
04/01/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPAIR BLOCKING AT SHEAR PANEL N.W. CORNER 2) FIREBLOCK STAIRWELL EAST WALL 3) FIRE BLOCK MISSING DOWNSTAIRS BATH SOUTH WALL 4) RED HEAD BASE PLATE DOWNSTAIRS BATH EAST WALL 5) SECURE ALL 90 VENTS THROUGH FIRST FLOOR 6) NAIL PROTECT KITCHEN DRAIN AT BASE PLATE 7) NAIL PROTECT BATH VENT DOWNSTAIRS 8) FIRESTOP TUB SHOES 9) FIRESTOP SHOWER NORTH WALL AT DROP 10) OVERSPAN AT BEARING WALL AT SMART WIRES. PROVIDE PROPER FIX 11) INSULATE ALL EXTERIOR TUB WALLS AND BLOCK SURROUND WALLS AND SHOWERS 12) NAIL PROTECT TOP PLATE UPSTAIRS WATER CLOSET VENT 13) NO WATER DWV SYSTEM 14) PEX OK |