Permit: T04CM05034

Parcel: 115041320


Addresses:

1327 N PARK AV #02


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM05034

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/04/2005 FRAMING Approved IVRS - Inspection :*
04/01/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPAIR BLOCKING AT SHEAR PANEL N.W. CORNER
2) FIREBLOCK STAIRWELL EAST WALL
3) FIRE BLOCK MISSING DOWNSTAIRS BATH SOUTH WALL
4) RED HEAD BASE PLATE DOWNSTAIRS BATH EAST WALL
5) SECURE ALL 90 VENTS THROUGH FIRST FLOOR
6) NAIL PROTECT KITCHEN DRAIN AT BASE PLATE
7) NAIL PROTECT BATH VENT DOWNSTAIRS
8) FIRESTOP TUB SHOES
9) FIRESTOP SHOWER NORTH WALL AT DROP
10) OVERSPAN AT BEARING WALL AT SMART WIRES. PROVIDE PROPER FIX
11) INSULATE ALL EXTERIOR TUB WALLS AND BLOCK SURROUND WALLS AND SHOWERS
12) NAIL PROTECT TOP PLATE UPSTAIRS WATER CLOSET VENT
13) NO WATER DWV SYSTEM
14) PEX OK