Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/13/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STAIR RISE EXCEEDS 7 3/4" 2) OK TO INSULATE AND DRYWALL ALL BUT STAIR AREA |
|
| 01/11/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) DBL TOP PLATE OF P-1 SHEAR CANNOT BE CUT OR NOTCHED. HAVE ENGINEER PROVIDE REPAIR 2) CLIP KITCHEN P-1 SHEAR TO TRUSS WITH 6 A35 CLIPS 5) STAIRS NOT PER 49/AD3 6) DBL TOP PLATE SPLICES CANNOT BE WITHIN 48" OF EACH OTHER 7) 4 X 8 BEAM MUST BEAR ON HANGER IN GARAGE. FILL ALL NAIL HOLES IN HANGER 8) STUD MISSING P-1 SHEARWALL 9) PEX CANNOT BE WITHIN 12" OF CAN LIGHTS 10) STOPPED INSPECTION, TOO MANY ITEMS |
|
| 01/07/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) STUCCO LATH MUST BE COMPLETE AND APPROVED PRIOR TO INTERMEDIATES INSPECTION |