Permit: T04CM05018

Parcel: 11804173D

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/14/2005 FRAMING Approved IVRS - Inspection :*
01/13/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) P3 SHEARWALL NOT NAILED TO FLOOR TRUSS AT 4" ON CENTER
2) ITEMS 1, 3, 11, 13 AND 17 FROM 1/11/05 INSPECTION NOT COMPLIED WITH
01/11/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) PEX LINES MUST BE WITHIN 1/16" OF FITTING STOP COLLARS. WATER ENTRANCE
2) GARAGE P-3 SHEARWALL REQUIRES NAILS AT 3" ON CENTER AT EDGES AND NAILS MUST BE 3/8" FROM EDGES
3) W/H "B" VENT REQUIRES 1" CLEARANCE TO COMBUSTIBLE MATERIAL
4) PEX MUST BE 6" FROM "B" VENT
5) STAIRS NOT PER 53/AD3
6) RED HEAD ANCHOR BOLTS LOOSE
7) STAIR RISER EXCEEDS 7 3/4" FIRST STEP
8) RISER CHASE GREATER THAN 3/8" NOT ALLOWED
9) FLOOR PANELS NOT T & G JOINED SOUTHWEST BEDROOM
10) NO DWV WATER TEST 2ND FLOOR
11) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF WALL STUD SURFACE
12) FIRESTOP W/H "B" VENT 2ND FLOOR AND CEILING
13) DBL TOP PLATES OVER KNOTCHED. FILL ALL HOLES IN FHA STRAPS
14) PEX MUST BE 12" FROM RECESSED LIGHTS
15) OVERSPAN STUD MISSING 1/2 BATH SHEARWALL
16) FIRE STOP CHASE IN GARAGE
17) HORIZONTAL DWV MUST HAVE 1/4" PER FT PITCH
18) 2ND FLOOR PLATES NOT NAILED PER 1/SD2 OR 2/SD2
19) STOPPED INSPECTION, TOO MANY ITEMS
01/07/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) STUCCO LATH MUST BE COMPLETE AND APPROVED PRIOR TO INTERMEDIATES INSPECTION