Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA ELECTRIC
Permit Number - T04CM05002
Inspection Description - POOL/SPA ELECTRIC
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/19/2006 | POOL/SPA ELECTRIC | Approved | IVRS - Inspection :* | |
| 07/18/2006 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. POOL LIGHTS NEED TO ALL BE OPERATING AND HAVE GFI PROTECTION. 2. PANEL DIRECTORY IS NOT CORRECTLY LABELED. |
|
| 07/14/2006 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* STILL NEED TO MAKE CORRECTIONS #1, #2, #3, #6, #8 FROM PREVIOUS INSPECTION. |
|
| 06/07/2006 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. IDENTIFY PANEL DIRECTORY - NEC 408.4 2. BOND GAS PIPE - NEC 250.104 (B) 3. TIGHTEN ALL BONDING CONNECTIONS - NEC 110/250 4. PROVIDE 3' CLEAR SPACE IN FRONT OF PANEL - NEC 110.26 5. BOND FENCE AROUND POOL - NEC 680.26(B)(5) 6. RECEPTACLES NOT ALLOWED WITHIN 10' OF POOL OR HOT TUB - NEC 680.22 (A)(2) 7. I DO NOT BELIEVE THE CURRENT LOCATION OF THE EMERGENCY SHUT OFF FOR HOT TUB MEETS NEC 680.41 8. CHECK TO SEE IF POOL LUMINAIRE NEEDS GFI PROTECTION (I HAVE NO PLANS ON SITE). |
|
| 03/06/2006 | POOL/SPA ELECTRIC | Denied | NO ONE ON SITE -- NEED APPROVED PLANS AND GATE UNLOCKED -- CALL AND MAKE ARRANGEMENTS | |
| 03/02/2006 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection :* | |
| 09/27/2005 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection :* ISOLATE NEUTRAL FROM GROUNDING BUS AT PANEL & BOND GROUNDING BUS. BOND POOL FENCE |
|
| 09/26/2005 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 08/11/2005 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection :* 1) U.G. AS DISCUSSED WITH CARL |
|
| 12/15/2004 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection :* 1) POOL LIGHTS OK 2) OK TO GUNITE |