Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 05/05/2005 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection :*REVISED CITY APPROVED PLAN ON SITE |
| 03/04/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* CORRECTION MADE, RED LINE DRAWING FOR 3005 & 3035 TO BECOME REVISED CITY APPROVED PLAN TO BE SEEN AT LATER DATE .COVER AT OWN RISK. 1) BACKFLOW PROTECTION WILL BE REQUIRED FOR BOTH COFEE MAKERS AND SODA DISPENSER WHICH COLD REQUIRE (3) SEPARATE BACKFLOW DEVICES. |
| 03/02/2005 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* WATER TEST AT P-3 FLOOR SINK THRU ROOF WASTE & VENT OK. 1) PROVIDE REDLINE DRAWING OF WATER HEATER & HOSE BIB RELOCATION AT TIME OF INSPECTION FOLLOWED BY CITY APPROVED PLAN. 2) MID STORY SUPPORT REQUIRED AT VENT FROM P-3 AND VENT FROM P-1 FIXTURES. |
| 02/08/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF OK EXCEPT 1) NEED WASTER TEST ON FLOOR SINK ?? AT COOLER AREA THRU ROOF. 2) PROVIDE PERMANENT CAPS ON ALL DEMO PIPING 3) WRAP 3/4" COPPER H20 PIPING BELOW SLAB WITH 10 MIL TAPE OK POLY SLEEVE AT AREA WHERE CONTACT WITH CONCRETE PRIOR TO CONCRETE POUR BACK. 4) PROVIDE MID STORY SUPPORT OF ABS VENTS IN WALL. 5) CALL BACK FOR REINSPECTION PRIOR TO SHEET ROCK. |
| 01/18/2005 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* 1) WATER TEST P-3 FIXTURE AT NORTH WEST ??. ( BALL LOT GO) 2) CALL IN 03005 INSPECTION. 3) HAVE A RED LINE DRAWING OF YOUR INSTALLATION ON ISTE FOR FUTURE INSPECTION OR INSTALL PER YOUR APPROVED PLAN. |