Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM04997

Parcel: 10709071A


Addresses:

500 W GRANT RD


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T04CM04997

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
06/30/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :* 1) 708.0 04 UPC GRADE OF HORIZONTAL PIPING 18-5 94 UPC INSTALLATION STD FOR ABS. 2) ABS DWV UNDERGROUND OK. WATER TEST ONE RISER TO TEN FEET OK. 3) PLEASE NOTE: BEFORE YOU INSTALL BWV-CALL ME RICK MYERS 909-5157 CONCERNING ELEVATIONS. 4) 4" ABS SEWER TO WITHIN 10 FT OF CURB OK. CALL INSPECTION 3055 SEWER/HCS THIS INFORMATION CAN BE TRANSFERED TO THAT ACTIVITY NUMBER.
06/28/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :* 1) ALL DRAINAGE PIPING TO BE INSTALLED AT 2 % U.N.O. 2) BACKPITCHED SECTIONS AND SECTIONS WITH LESS THAN 2% GRADE ARE NOT PERMITTED. 3) PIPING TO BE LAID ON A FIRM BED, WITH CLEAN FILL. DEBRIS, ROCKS, CALICHI, ETC NOT PERMITTED