Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM04984
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/22/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
02/16/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) STRAP 2ND AND 1ST FLOOR TOGETHER 4'-0" 2) AB'S AT SHEAR WALLS |
|
02/10/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) ADD 2 X 6 AT S/W CORNER FOR P.A. 2) STRAP AT 1ST=2ND FLOOR INCLUDING PLYWOOD SHEAR 3) NEED RETRO H.D. AT REAR WALL ? 4) ENTRY TRUSSES, NO LEDGER 5) WIND BRACE AT WEST WALL 1ST FLOOR 6) A.B. SPACING AT SHEARWALLS 7) BLOCK AND NAIL PLY ROOF, TURNED PARALELL TO TRUSSES 8) #3 SHEAR A.B. 24" 9) #2 SHEAR A.B. 32" |