Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM04984

Parcel: 141014640

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM04984

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/22/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/16/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) STRAP 2ND AND 1ST FLOOR TOGETHER 4'-0"
2) AB'S AT SHEAR WALLS
02/10/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) ADD 2 X 6 AT S/W CORNER FOR P.A.
2) STRAP AT 1ST=2ND FLOOR INCLUDING PLYWOOD SHEAR
3) NEED RETRO H.D. AT REAR WALL ?
4) ENTRY TRUSSES, NO LEDGER
5) WIND BRACE AT WEST WALL 1ST FLOOR
6) A.B. SPACING AT SHEARWALLS
7) BLOCK AND NAIL PLY ROOF, TURNED PARALELL TO TRUSSES
8) #3 SHEAR A.B. 24"
9) #2 SHEAR A.B. 32"