Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/22/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/21/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TC CLIPS MISSING NAILS 2) BRACING REQUIRES 2 EACH 16D COMMONS AT PLATES 3) SHEAR IN BACK NOT NAILED 4) COMPLY WITH DETAIL 10/A8A AND 4/A8A 5) NO ROOF ACCESS 6) STOPPED INSPECTION |