Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM04956
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/22/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
03/21/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TC CLIPS MISSING NAILS 2) BRACING REQUIRES 2 EACH 16D COMMONS AT PLATES 3) SHEAR IN BACK NOT NAILED 4) COMPLY WITH DETAIL 10/A8A AND 4/A8A 5) NO ROOF ACCESS 6) STOPPED INSPECTION |