Permit: T04CM04943

Parcel: 116094000


Addresses:

750 N LEUTEA DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/07/2005 FRAMING Approved IVRS - Inspection :*
REINSPECT
09/06/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TERMINATE WIRES IN GARAGE CEILING
2) TIGHTEN ANCHOR BOLTS
3) FIREBLOCK FR FIREPLACE
4) FIREBLOCK ALL DROP CEILINGS
5) EXTEND FURNACE B-VENTS AND SECURE WITH 1" CLEARANCE TO COMBUSIBLES
6) TERMINATE LIGHT FIXTURES INTO CUT-IN BOXES TO BE CHECKED AT SHEETROCK NAILING
7) GAS PRESSURE TEST REQUIRES 3 LB MIN FOR 15 MINUTES