Permit: T04CM04943

Parcel: 116094000


Addresses:

750 N LEUTEA DR

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
07/27/2005 ROOF NAILING Approved IVRS - Inspection :*
07/25/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PORCH LEDGERS TO HAVE A.35/H2.5 CONNECTION
2) FRONT PORCH COLUMN NOT DONE
3) REAR PORCH COLUMN NOT DONE
4) GROUNDING ELECTODE CONDUCTOR CONNECTED TO WRONG SIDE OF PANEL (INSTALL ON SIDE WHERE BREAKERS AREA)
5) INSTALL H2.5'S TRUSSES AT BEARING
6) NEED APPROVED TRUSS DRAWINGS
7) NEED LONG EXTENSION LADDER TO INSPECT ROOF
8) STOPPED INSPECTION