Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM04930
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/08/2005 | FRAMING | Approved | IVRS - Inspection :* 1) PROVIDE ENGINEERED FIX FOR CONCRETE BUST OUT AT LAUNDRY ROOM |
|
| 02/07/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) REPAIR UNDERSLAB NOT COMPLETED/NO WATER DWV |
|
| 01/27/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* NOT REQUIRED |
|
| 01/26/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRAMING TO BE APPROVED WHEN ALL TRADES ARE COMPLETED 2) COMPLY WITH PRIOR INSPECTION 3) GROUND METAL BOX AT FRONT ENTRY 4) NO WATER DWV SYSTEM, PEX LINES OK 5) GROUT TUB SHOES 6) OK TO INSULATE 7) PLEAS EXPOSE ALL DWV SYSTEM |
|
| 01/25/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 01/21/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH DETAIL 7C/SD-1 LOOSE ANCHOR BOLTS AT GARAGE SHEARWALL 2) CONTINUE SHEAR PANEL TO TOP PLATE ABOVE GARAGE ENTRY DOOR 3) SEAL ELECTRIC BOX BY HOSE BIB WEST WALL 4) COMPLETE STUCCO WEST MASTER BATH WINDOW 5) SEAL A/C 220 LINES 6) GROUND ALL METAL BOXES 7) NAIL PROTECT ROMEX TOP PLATE WEST GARAGE WALL 8) NO WATER IN DWV SYSTEM 9) GROUT TUB SHOES 10) PROVIDE PROPER REPAIR TO TOP PLATE AT STOVE VENT 11) TO MANY ITEMS STOPPED INSPECTIONS AT BATHROOM 12) PROVIDE TRUSS CALC'S |