Permit: T04CM04930

Parcel: 110034940

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM04930

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/08/2005 FRAMING Approved IVRS - Inspection :*
1) PROVIDE ENGINEERED FIX FOR CONCRETE BUST OUT AT LAUNDRY ROOM
02/07/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) REPAIR UNDERSLAB NOT COMPLETED/NO WATER DWV
01/27/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
NOT REQUIRED
01/26/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FRAMING TO BE APPROVED WHEN ALL TRADES ARE COMPLETED
2) COMPLY WITH PRIOR INSPECTION
3) GROUND METAL BOX AT FRONT ENTRY
4) NO WATER DWV SYSTEM, PEX LINES OK
5) GROUT TUB SHOES
6) OK TO INSULATE
7) PLEAS EXPOSE ALL DWV SYSTEM
01/25/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
01/21/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH DETAIL 7C/SD-1 LOOSE ANCHOR BOLTS AT GARAGE SHEARWALL
2) CONTINUE SHEAR PANEL TO TOP PLATE ABOVE GARAGE ENTRY DOOR
3) SEAL ELECTRIC BOX BY HOSE BIB WEST WALL
4) COMPLETE STUCCO WEST MASTER BATH WINDOW
5) SEAL A/C 220 LINES
6) GROUND ALL METAL BOXES
7) NAIL PROTECT ROMEX TOP PLATE WEST GARAGE WALL
8) NO WATER IN DWV SYSTEM
9) GROUT TUB SHOES
10) PROVIDE PROPER REPAIR TO TOP PLATE AT STOVE VENT
11) TO MANY ITEMS STOPPED INSPECTIONS AT BATHROOM
12) PROVIDE TRUSS CALC'S