Date Description Inspector Results Comments
03/17/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/17/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BANG PLATES MISSING AT ABS PIPE
2) 2 NAILS MINIMUM REQUIRED AT METAL BRACE TOP AND BOTTOM PLATE
3) FASTENERS MISSING WEST END AT HIGH GABLE
4) SHEAR TRANSFER REQUIRES #8D'S AT 4" ON CENTER AT GARAGE WALL
5) NEED APPROVED TRUSS DRAWINGS ON SITE