Permit: T04CM04921

Parcel: 137340010


Addresses:

1650 W VALENCIA RD


Inspection Status: Approved

Inspection History: PLUMBING - ABOVE CEILING

Permit Number - T04CM04921

Inspection Description - PLUMBING - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
04/13/2005 PLUMBING - ABOVE CEILING Approved
03/09/2005 PLUMBING - ABOVE CEILING Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SEE NOTES # 1,3,5,6,7 AND NOTE: #3 FROM PREVIOUS INSPECTION ON 03/01/05 2) CANNOT LOCATE A THREADED FITTING IN A CONCEALED LOCATION FOR TEST TEES. 3) AIR PRESSURE TEST FOR DWV REQUIRES A MINIMUM OF 5LBS. 4) SHALL PAY A RE-INSPECTION FEE PRIOR TO THE NEXT INSPECTION.
03/07/2005 PLUMBING - ABOVE CEILING Not ready for Inspection IVRS - Inspection :* 1) NOT READY FOR INSPECTION
03/02/2005 PLUMBING - ABOVE CEILING Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) C.O SHALL BE N A VERTICAL POSITION OR POSITIONED ABOVE CENTER LINE OF TRAD ARM. 2) P-TRAP IS REVERSED @ SINK IN PHOTO AREA. 3) TRAP ARM IS 2" THEN R-TRAP SHALL BE 2". THE TRAP SHALL BE THE SAME SIZE AS THE DRAIN SERVED. 4) SHALL PROVIDE A WATER TEST ON DWV SYSTEM 5) HORIZONTAL VENT ABOVE CEILING HAS BACK PITCH 6) REMOVE C.O TEE IN CEILING 7) EXPOSE P.O.C OF 2" WASTE FOR PHOTO SINK AND VENT P.O.C ABOVE CEILING. 8) SEE NOTE#3 FOR PHOTO LAB
03/01/2005 PLUMBING - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*
1) EXPANSION TANK NOT SUPPORTED
2) PIPING NOT STRAPPED
3) BACKFLOW DEVICES TO BE TESTABLE TYPE
4) SUBMERSIBLE INLET REQUIRES ? OR EQUAL ONE FOR EYEWASH AND ONE FOR SPRAYER
5) CLEANOUT FOR SINK NOT ACCESSIBLE
6) NO PAN DRAIN FOR WATER HEATER
7) MAY NOT BE A COMPLETE LIST
02/24/2005 PLUMBING - ABOVE CEILING Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) AIR PRESSURE TEST FOR COMBINATION WASTE & VENT SYSTEM IS OK. 2) P.O.C OF C.W.V TO EXISTING BLDG. DRAIN IS OK. 3) OK TO BACKFILL TRENCH. 4) NOTE: SHALO REDUCE 3" P-TRAP@ TOP OF W?? TO 2" FOR BUN?. 5) SHALL PROVIDE A 3" COMBO FOR C.O EXTENTION. 6) SOIL WATER TEST IS OK FOR FLOOR SINK@ CUSTOMER SERVICE AREA. 7) SHALL USE PROPER TRANSITION FROM ABS TO PVC @ P.O.C OF FLOOR SINK.
02/23/2005 PLUMBING - ABOVE CEILING Denied 1) 3/4" C.W SUPPLY GOING UP INTO CEILING IS LOOSE.