Permit: T04CM04895

Parcel: 140377110


Addresses:

6952 S MARTLET DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/11/2005 FRAMING Approved IVRS - Inspection :*
03/09/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEAL PENETRATIONS FROM 1ST TO 2ND FLOOR
2) WATER LINE MUST HAVE 12" CLEARANCE FROM CAN LIGHTS
3) 16 GA STRAP REQUIRES 16D NAILS NOT TECOS
4) ELECTRIC OUT OF WALL UNDER STAIRS
5) NAIL PROTECT ELECTRIC IN DINING ROOM
6) SEAL MECH CHASES
03/07/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) MANY DOUBLE AND TRIPPLE 2 X POSTS MISSING UNDER GLU LAM BEAM LIVING ROOM
2) TRIPPLE KING STUDS MISSING WEST WALL
3) NAILS IN FAMILY ROOM P-3 DRIVEN TO DEEP
4) P-1 SHEAR PANEL MISSIN BY GLU LAM BEAM, SEE NOTES S-2.1
5) STOPPED INSPECTION, TO MANY ITEMS