Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM04895

Parcel: 140377110


Addresses:

6952 S MARTLET DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/17/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/16/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT PLUMBING OUTSIDE
2) COMPLY WITH SEC 602.6.1 DRILLING AND NOTCHING OF TOP PLATE
02/15/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) H2.5'S REQUIRED STUDS AT BEAM AT FRONT ENTRY
2) EXPOSE FRONT ENTRY COLUMN BETTER, UNABLE TO SEE ANCHORS
02/15/2005 EXT METAL CLIPS/EXT SHEATHING Denied 1) STUDS BOTTOM OF GLB TO SHORT
2) NAIL PROTECT PLUMBING
3) LADDER NOT PROPERLY SECURED
4) NAIL OVER PENETRATED SHEAR
5) PATIO LEDGER NOT NAILED
6) CHECK SHEAR SHINNERS
02/11/2005 EXT METAL CLIPS/EXT SHEATHING Cancelled CANCELLED PER LOURDES OF K.B. HOMES
02/10/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TO WINDY TO WALK ROOF
2) NAILS SET TOO DEEP SHEATHING
3) STOPPED INSPECTION
4) COMPLETE AND RECALL