Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/24/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/23/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPAIR SHEER PANEL. 2) COMPLY WITH DETAIL 6ASD3 |
|
| 02/22/2005 | FRAMING | Cancelled | CANCELLED PER LOURDES OF K.B. HOMES 907-6014 | |
| 02/18/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE BLOCK CHASES AT GARAGE ENTRY BOTH SIDES 2) 10SD4 NOT COMPLIED WITH 3) REPLACE SHEAR PANEL PER 4SD4 4) FIREBLOCK FRONT WINDOW CHASE 5) OVERSPAN AT GARAGE SHEAR 6) PLAN CALLS OUT (6A SD3) DETAIL (6A) BEING USED NOT CALLED OUT |
|
| 02/17/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO TEST ON DWV'S 2) REPLACE BLOCKING PANEL 3) DETAIL 10SD4 NOT PER PLAN 4) CLEANOUTS NOT PER PLAN 5) COMPLY WITH DETAIL 5SD3 6) COMPLY WITH DETAIL 6SD3 7) STOPPED INSPECTION |