Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T04CM04885
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/11/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* 1) 3" N/H VENT STRAPPED ON WALL AND TERMINATES NEXT TO VERTICAL SURFACE AT PLUS OR MINUS EIGHT FEET |
|
| 05/24/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) 1,500 GAL INTERCEPTOR INSTALLED WITH ALL DOWNSTREAM PLUMBING, INCLUDING VENT. HAVE ARCHITECT DIRECT YOU TO TERMINATE VENT. CONNECTION TO EXISTING OK 2) OK TO COVER |
|
| 04/29/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*1) 4" BRANCH BETWEEN COLUMN 6 & 7 OFF OF 4" MAIN, TO MOP SINK OK. WATER TEST OK. 2) 8" DECK DRAIN WASTE ATTACHED AT COLUMN # 7 AND EXTENDED TO ABOVE GRADE WITH 2" BRANCH TO COLUMN 10 OK. TO COVER AS REDLINED ON P2.1 SUBJECT TO REVISED APPROVED PLAN | |
| 04/28/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) UNABLE TO LOCATE PLUMBER. HE HAS REDLINE DRAWINGS I NEED TO DO MY INSPECTION. | |
| 04/25/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
| 04/22/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) NOT INSTALLED PER PLAN-RED LINES ON SITE 2) BLDG DRAIN FROM GRID LINE #6 TO #10 OK TO COVER SUBJECT TO REVISED APPROVED PLAN |
|
| 03/30/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1_ 4" N/H BRANCH DRAIN ALONG COLUMN 3 4 AND STUBBED UP-OK. OK TO COVER. | |
| 03/22/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) STORM DRAIN PIPING UNDERGROUND WITH 2-4" BRANCHES FOR DECK DRAINS ( NOT INSTALLED) OTHER BRANCHES ARE STUBBED UP ON COLUMNS. AS REDLINED ON P2.1 OK TO COVER 12" -10" -8" STOPS BETWEEN COLUMN # 6 & #7 AS NOTED ON PLAN | |
| 03/17/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) SOIL WATER TEST IS OK. 2) HCS CONNECTION TO 6" EXSISTING HCS IS OK. 3) NOTE: THIS INSPECTION IS FOR 4" BLDG. DRAIN AS PER RED LINES AND INITIALED BETWEEN GRID LINES # 1 EAST TO GRID LINE # 6 AND BETWEEN GRID B NORTH TO ? AS NOTED ON PLAN. 4) OK TO BACKFILL TRENCH. |