Permit: T04CM04885

Parcel: 117120010


Addresses:

110 E PENNINGTON ST

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
05/02/2005 REINFORCED MASONRY PRE-GROUT Approved TOP OF STAIR N OF RAMP OK
04/22/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* PARTIAL
04/19/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* 1ST LEVEL A.8/6-7 8'; STAIR AJ C IP RETAIN WALL OK.
04/15/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* RAMP WALLS GROUTED-BOND BEAN & TOP TO BE SLUGGED IN.
04/14/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*TOP OUT @ SHOP OK ( LESS OPENING)
04/13/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* YOU NEED BOND BEAM TOP OF RAMP WALLS. WF1 FOOTING NORTH OF RAMP NOT LAYERED OUT PROPERLY
04/12/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/11/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/08/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/07/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* STEM BY ELEVATOR A.8/G-7
04/06/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* 8' SHARP PERIMETER NOTE: PER GSN MISSING MCJ @ CENTER OF SOUTH WALL. PROVIDE RFI.
04/05/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* LIFT@RAMP SIDES TO HIGH POINT SLAB
04/04/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* RAMP WALLS WATER PROTECTED. OK TO BACKFILL TO 1ST BOND BEAM.
04/01/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* PROGRESS NO COMPLETE LIFT
03/31/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* OK RAMP WALL TO 1ST BOND BEAM
03/30/2005 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
03/29/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* STEMS 12"@ RAMP AND 4'LIFT @ SHOP
03/28/2005 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) NO INSPECTIONS WERE EVER CALLED FOR FOOTINGS OR FOUNDATIONS. I CANNOT APPROVE WORK ATTACHED TO AND DEPENDING ON NON APPROVED WORK. 2) CONTRACTOR STATES THAT THEY WERE TOLD BY TRANSPORTATION DEPT PHIL SABIN & CHIS LEIGHTON THAT THEY WERE ONLY GOING TO HAVE SPECIAL INSPECTION AND NOT DSD.