Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T04CM04885
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/08/2005 | BUILDING PRE-SLAB | Approved | IVRS - Inspection :* | |
| 07/21/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* 1) ENTRY SLABS AT WEST OK |
|
| 06/20/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* FOOTING FOR WINDOW WALLS 1-7 OK | |
| 06/09/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* TOP OF EACH BASIN OK. | |
| 06/06/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* CATCH BASIN WALLS TO TOP | |
| 06/02/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* PARTIAL A-B/4-12 | |
| 05/25/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* 1) P; B-B.7/7-11 SOG OK |
|
| 05/20/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* 1) CATCH BASIN WALLS AND BASE |
|
| 05/18/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* LEVEL 2 6-10 OK TO POUR WHEN SP INSP CONFIRMS REPAIR NOTED BELOW. 1) DO NOT RUN FELT PAPER OVER RABBIT EARS ( LINE9, LINE 10). 2) SPACE CHORD STEEL 3" O.C AND TIE DOWN AS NECESSARY. | |
| 05/17/2005 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection :* | |
| 05/16/2005 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection :* 1) DETAIL PROVIDED DOES NOT SHOW HOW THICK WALLS ARE. 2) REBAR REQUIRES 1 1/2" CLEAR FROM FROM AND 3" CLEAR FORM DIRT. | |
| 05/12/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* ALL TOPPING SLAB OK TO PLACE. NOTE: BOTH MYSELF AND SPECIAL INSPECTOR MISIDENTIFIED LEVEL 5 AS LEVEL 4 ON 4/15/05. THE EXTRA CHORD STEEL ON LINE A IS ACTUALLY IN LEVEL 6 ( WE ALSO MISIDENTIFIED LEVEL 6 AS LEVEL 5) ALL STEEL IS CORRECT OR THERE IS EXTRA ON ALL TOPPING SLABS | |
| 05/11/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :*DENIED 1) 10 EACH #5 CHORD BARS REQUIRED ALONG LINE A LEVEL 5. 2) AT LEVEL 6-7 USE LEVEL 7 DETAIL @ LINE 9 | |
| 05/09/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* | |
| 05/06/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :*LEVEL 3-4/6-10 AND LEVEL 4-5 /6-10 OK TO PLACE CONCRETE. | |
| 05/05/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* TOPPING SLAB LEVEL 2-3/AREA 6-10 OK TO PLACE WHEN SPECIAL INSPECTOR CONFIRMS 1) ADDITION 2 EACH 8' CHORD BAR EXTENSIONS @ B -12. 2) UNTWIST OVERLAPPED CHORD STELL @ B-12. 3) PULL " RABBIT EAR" EMBEDS OFF DECK AS NECESSARY TO ENSURE PROPER CONCRETE FLOW AROUND EARS TO BOND TO EMBEDS. | |
| 05/02/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* RAMP UP OK AND STAIR N SIDE OF RAMP OK. | |
| 04/27/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* SEE YESTERDAYS NOTES | |
| 04/26/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* LEVEL 7 F.O ELEVATOR & SHOP S.O.G | |
| 04/22/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* PRESLAB- LEVEL 1 AREA A-B/3-S?? OK | |
| 04/19/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* SEE YESTERDAY | |
| 04/18/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* LEVEL 4 AREA 1-6 AND LEVEL 2 AREA 1-6 | |
| 04/11/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* | |
| 04/08/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* | |
| 04/06/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* LEVEL 6 AREA 1-6 OK TO POUR. PLEASE TIE DRAG & CH?? BARS @ 3" O,C. BEFORE POUR. PLEASE HAE THEM SPACED & TIED FOR SUBSEQUESNT INSPECTIONS. | |
| 03/30/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* LEVEL 3 GRIDS 1-605/A-C TOPPING SLAB OK TO PLACE. |