Date Description Inspector Results Comments
02/08/2005 FRAMING Approved IVRS - Inspection :*
02/07/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL RED HEAD ENTRY DOOR
2) FRAMING TO BE APPROVED WHEN ALL TRADES ARE COMPLETED
3) SEAL ALL PENETRATIONS
4) COMPLETE MESH NORTH GABLE
5) COMPLY WITH 10/SD4 NAILING PATTERN 6" ON CENTER
4) MISSING CRIPPLE STUDS EAST LIVING ROOM WINDOWS
5) NO WATER DWV SYSTEM
6) PEX OK