Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM04869
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/23/2005 | FRAMING | Approved | IVRS - Inspection :* | |
02/22/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK TO INSULATE. DO NOT COVER REPAIRS 2) RANGE HOOD-DBL TOP PLATE SHEAR WALL CUT INSTALL TWO FHA STRAPS ONE SIDE WITH 6-16D NAILS EACH END OF STRAP |
|
02/17/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DBL STRAP REQUIRED WHERE DBL PLATE IS BREACHED WITH 6-16D NAILS EACH STRAP EACH SIE 2) COMPLY WITH SHEARWALL #5 NAILING SCHEDULE 3) SECURE WIRES WITHIN 12" OF ELECTRIC SERVICE PANEL 4) NO WATER TEST ON TOP-OUT |
|