Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM04869
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/03/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
02/01/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOTHING DONE FROM LAST INSPECTION 2) CLIPS MISSING NAILS 3) WIND BRACES MISSING NAILS 4) LADDER NOT SECURED AND LOAD CAPACITY TO LOW |
|
01/31/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1 2X6 CHANNEL NOT FRAMED AT KITCHEN WALL 2 USE APPRV NAIL PROTECTION FOR ELEC CONDUIT @ KITCHEN WALL 3 REPAIR ARMAFLEX 4 RIBBON NOT NAILED 5 STOPPED INSP/NO ACCESS TO ROOF |
|
01/24/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MAS STRAP MISSING LEFT SIDE OF GARAGE 2) INSULATE CHANNELS 3) NAIL PROTECT PLUMBING AND ELECTRICAL FROM OUTSIDE 4) PROVIDE ACCESS TO ROOF |