Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/23/2005 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 02/22/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO WATER IN DWV SYSTEM 2) NAIL PROTECT BATHROOM VENT AT TOP PLATE 3) NAIL PROTECT LAUNDRY TRAP 4) NAIL PROTECT CONDENSATE LINE 5) BLOCK REGISTER LAUNDRY ROOM 3 SIDES 6) PROVIDE LONGER STRAP AT OVER KNOTCH MECHANICAL ROOM 7) TOP PLATE 8 16D NAILS EAST END |
|
| 02/19/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/17/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |