Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/24/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/23/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 02/22/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FHA STRAP TOP PLATES AT HOMERUNS 2) SECURE DRYER DUCT AT BOTTOM |
|
| 02/18/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 02/01/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CONNECT BATH EXHAUST DUCT TO EXTERIOR 2) INSTALL MISSING HOLDOWNS 3) INSTALL MISSING METAL CONNECTORS ALL TRUSSES AT BEARING 4) INSTALL BANG PLATES ELECTRIC WITHIN 1 1/4" OF STUD FACE 5) INSTALL BANG PLATE PLUMBING WITHIN 1 1/2" OF STUD FACE 6) NO TEST DWV 7) STOPPED INSPECTION |