Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM04815
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/29/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
03/28/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
03/24/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ADD FRAMING CLIPS AT EACH SIDE FRONT OF GARAGE WHERE STUD MISSED 2) ONE TRUSS NOT NAILED NORTH SIDE MIDWAY IN HOUSE 3) REPLACE COLLAPSED PORTION OF SOLE PLATE SOUTH SIDE OF GARAGE 4) ADD H2.5 1ST TRUSS SOUTH SIDE GARAGE 5) CROSS BRACE GARAGE TRUSSES 6) OVERSPAN TRUSS BETWEEN GARAGE AND HOUSE (28") |