Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T04CM04792
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/01/2005 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* RELOCATE ELEC. CONDUIT BLOCKING ACCESS TO FAN COIL. PROVIDE A LARGER ACCESS OPENING. CAP OFF UNUSED CONDENSATE OUTLETS. WILL CHECK ON FINAL. | |
12/20/2004 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/PROVIDE A SECONDARY DRAIN PAN ON FAN COILS. SECONDARY DRAIN TO TERMINATE TO A CONSPICUOUS LOCATION PROVIDE BACKING AROUND CEILING BOXES IN RESTROOMS. PROVIDE ACCESS TO FAN COIL ABOVE HARD LID. HAVE PLANS REVISED TO SHOW STRUCTURAL INTEGRITY IF USING BATHROOM CEILING AS A SERVICE PLAT FORM FOR FAN COIL. |